The control and measuring point of KIP.PSS (lifting and sliding) is a switching equipment designed for electrochemical protection and control of the corrosion condition of underground metal structures, providing convenient access to contact clamps and cables from all sides.
Read more
Description
The control and measuring point KIP-PSS is equipment designed for electrochemical protection and control of the corrosion condition of underground metal structures. Manufactured according to TU 28.99.39.085-73892839-2018 .
The product corresponds to the type of climatic design U1, UHL1 or HL1 with the placement category 1 according to GOST 15150-69 and retains its parameters during the influence of external climatic factors, such as low and high temperatures (from minus 60 ° C to plus 40 ° C), solar radiation, physico-chemical effects of soil and bioorganisms.
Features
The KIP-PSS rack is made of polymer or composite materials that do not support gorenje. The rack is made with a height of 2500 mm, has a square with a side of 200 ± 10 mm in cross section and with a wall thickness of at least 4 mm. At the request of the customer, the product can be manufactured with reinforced fiberglass or metal rack corners, as well as be equipped with various additional equipment: a BZT pipeline protection unit; a UZT pipeline protection device; diode-resistor BDR (M), BDZ, BSZ units; a small-sized SCZ cathodic protection station.
Telemetry
KIP-PSS can be supplemented with equipment for telemetry and remote control, which provides more economical, prompt and accurate tracking of the correct operation of cathodic protection systems than the data obtained during the work of crawlers, and also significantly reduces the risks of emergencies in electrochemical protection systems.
T1 – connection via the "current loop" communication channel with physical signals (analog (4-20 mA) and discrete);
T2 – connection to the converter via serial digital interface RS-485, Modbus RTU protocol;
T3 – connection via GSM/GPRS communication channel version 1 (basic);
T4 – connection via GSM/GPRS communication channel version 2 (with two SIM cards);
T5 – connection via GSM/GPRS communication channel version 3;
T6 – connection to the converter via a radio channel (in the UHF band or others).
At the request of the customer, combinations of types of telemetry can be implemented. In this case, the designation is carried out as follows:
The product corresponds to the type of climatic design U1, UHL1 or HL1 with the placement category 1 according to GOST 15150-69 and retains its parameters during the influence of external climatic factors, such as low and high temperatures (from minus 60 ° C to plus 40 ° C), solar radiation, physico-chemical effects of soil and bioorganisms.
Features
The KIP-PSS rack is made of polymer or composite materials that do not support gorenje. The rack is made with a height of 2500 mm, has a square with a side of 200 ± 10 mm in cross section and with a wall thickness of at least 4 mm. At the request of the customer, the product can be manufactured with reinforced fiberglass or metal rack corners, as well as be equipped with various additional equipment: a BZT pipeline protection unit; a UZT pipeline protection device; diode-resistor BDR (M), BDZ, BSZ units; a small-sized SCZ cathodic protection station.
Telemetry
KIP-PSS can be supplemented with equipment for telemetry and remote control, which provides more economical, prompt and accurate tracking of the correct operation of cathodic protection systems than the data obtained during the work of crawlers, and also significantly reduces the risks of emergencies in electrochemical protection systems.
T1 – connection via the "current loop" communication channel with physical signals (analog (4-20 mA) and discrete);
T2 – connection to the converter via serial digital interface RS-485, Modbus RTU protocol;
T3 – connection via GSM/GPRS communication channel version 1 (basic);
T4 – connection via GSM/GPRS communication channel version 2 (with two SIM cards);
T5 – connection via GSM/GPRS communication channel version 3;
T6 – connection to the converter via a radio channel (in the UHF band or others).
At the request of the customer, combinations of types of telemetry can be implemented. In this case, the designation is carried out as follows:
- T13 is a combination of types T1 and T3
- T25 – combination of T2 and T5 types
- T124 is a combination of types T1, T2 and T4, etc.
- The paint durability guarantee is 15 years
- The plastic of the case is resistant to mechanical and thermal influences
- The anchor mechanism prevents the free removal of the pile from the ground
- The possibility of branding and applying any necessary information to the case
- The possibility of mounting a wide range of devices inside the KIP (low-power cathodic protection station, UZT, BSZ, Telemetry unit, UKT)
- The possibility of connecting telemetry from alternative power sources (solar panels)
How to buy
To purchase equipment, leave a request on the website or contact us:
The manager will contact you to clarify the parameters of the equipment and order details.
The exact cost, terms and conditions of delivery are calculated after filling out a questionnaire or clarifying the requirements for equipment.
The information on the site is only for introductory purposes. Not a public offer.
Our experts will answer any question about the product
|
Ask a question
|