The IPKZ-M-RA® pulse converter is an equipment used as part of the electrochemical corrosion protection system for underground parts of metal structures. The modified version of the IPKZ is characterized by more compact dimensions and low power.
Read more
Description
The modified Raduga IPKZ-M-RA® pulse converter of cathodic protection, built on the basis of pulsed power supplies, is designed for electrochemical (cathodic) protection of various underground metal structures: main pipelines (gas pipelines, oil pipelines, product pipelines and other pipelines for various purposes), utility facilities, storage tanks and other similar facilities, located in various soils, including soils with increased aggressiveness.
In cases of operation of the converter along railway tracks (tram tracks, metro) or in places where stray currents may appear, it is necessary to provide additional installation of drainage devices for trouble-free operation of the converter.
The converters are manufactured in a climatic version of the placement category 1, designed for outdoor installation and comply with GOST R 51164-98, GOST 9.602-2016.
IPKZ-M-RA® is characterized by small dimensions and light weight, can be used as a temporary station during the commissioning of the ECZ system. At the request of the customer, execution with a digital control unit is possible.
Functionality
- Ensuring the measurement of the polarization potential according to GOST 9.602-2016.
- Operation in the mode of automatic maintenance of the total or polarization potential at a given level.
- Operation in the mode of automatic stabilization of the protective current.
- Operation in the mode of automatic stabilization of the output voltage.
- Automatic transition to the output current stabilization mode at a given level when the reference electrode circuit is broken.
- Alarm about the occurrence of a break in the circuit of the reference electrode or potential sensor with automatic transition to the output current stabilization mode, at the level that was before the accident occurred.
- Calculation and indication of the time when the structure is under cathodic protection.
- Counting and indication of the time when the converters are under the voltage of the supply network, in the switched-on state.
- Short circuit protection in the load circuit with automatic switching to operating mode after the short circuit is eliminated.
- Overload, overvoltage and overheating protection.
- Automatic activation in the set mode when the supply voltage disappears and reappears (in case of power outages).
- All information about the output data, operating mode and other parameters of the converter is displayed on the LED display.
Types of telemetry:
T1 – connection via the "current loop" communication channel with physical signals (analog (4-20 mA) and discrete);
T2 – connection to the converter via serial digital interface RS-485, Modbus RTU protocol;
T3 – connection via GSM communication channel version 1 (2 SIM cards, data transmission via SMS messages);
T4 – connection via GSM/GPRS communication channel version 2 (2SIM cards, data transmission via TCP protocol);
T5 – connection via GSM/GPRS communication channel version 3 (specify the necessary telemetry in the additional requirements).
Combinations of telemetry types can be implemented into converters. In this case, the designation should be carried out as follows:
T13 – a combination of types T1 and T3
T25 – combination of T2 and T5 types
T124 is a combination of types T1, T2 and T4, etc.
In cases of operation of the converter along railway tracks (tram tracks, metro) or in places where stray currents may appear, it is necessary to provide additional installation of drainage devices for trouble-free operation of the converter.
The converters are manufactured in a climatic version of the placement category 1, designed for outdoor installation and comply with GOST R 51164-98, GOST 9.602-2016.
IPKZ-M-RA® is characterized by small dimensions and light weight, can be used as a temporary station during the commissioning of the ECZ system. At the request of the customer, execution with a digital control unit is possible.
Functionality
- Ensuring the measurement of the polarization potential according to GOST 9.602-2016.
- Operation in the mode of automatic maintenance of the total or polarization potential at a given level.
- Operation in the mode of automatic stabilization of the protective current.
- Operation in the mode of automatic stabilization of the output voltage.
- Automatic transition to the output current stabilization mode at a given level when the reference electrode circuit is broken.
- Alarm about the occurrence of a break in the circuit of the reference electrode or potential sensor with automatic transition to the output current stabilization mode, at the level that was before the accident occurred.
- Calculation and indication of the time when the structure is under cathodic protection.
- Counting and indication of the time when the converters are under the voltage of the supply network, in the switched-on state.
- Short circuit protection in the load circuit with automatic switching to operating mode after the short circuit is eliminated.
- Overload, overvoltage and overheating protection.
- Automatic activation in the set mode when the supply voltage disappears and reappears (in case of power outages).
- All information about the output data, operating mode and other parameters of the converter is displayed on the LED display.
Types of telemetry:
T1 – connection via the "current loop" communication channel with physical signals (analog (4-20 mA) and discrete);
T2 – connection to the converter via serial digital interface RS-485, Modbus RTU protocol;
T3 – connection via GSM communication channel version 1 (2 SIM cards, data transmission via SMS messages);
T4 – connection via GSM/GPRS communication channel version 2 (2SIM cards, data transmission via TCP protocol);
T5 – connection via GSM/GPRS communication channel version 3 (specify the necessary telemetry in the additional requirements).
Combinations of telemetry types can be implemented into converters. In this case, the designation should be carried out as follows:
T13 – a combination of types T1 and T3
T25 – combination of T2 and T5 types
T124 is a combination of types T1, T2 and T4, etc.
How to buy
To purchase equipment, leave a request on the website or contact us:
The manager will contact you to clarify the parameters of the equipment and order details.
The exact cost, terms and conditions of delivery are calculated after filling out a questionnaire or clarifying the requirements for equipment.
The information on the site is only for introductory purposes. Not a public offer.
Our experts will answer any question about the product
|
Ask a question
|