Copper/Copper Sulfate Reference Electrode ENES-RE-4M
Intended Use
The Copper / Copper Sulfate (Cu/CuSO) Reference Electrode is designed to measure the polarization potential and underground structure potential relative to the electrode by creating an electrolytic contact with the ground in circuits for determining the effectiveness of anti-corrosion protection of underground metal structures, as well as in systems for automatic control and regulation of the operating mode of cathodic protection installations. The measuring devices are connected to copper sulfate electrodes to calculate the polarization potential. Through the use of the obtained values, the required potential difference at the protected object is maintained.
Description
It consists of an electrolytic chamber, filled with electrolyte and a chamber filled with a bentonite mixture between which there is a membrane and a diaphragm, a copper rod connected by a cable with a tip and a potential sensor. During installation, the plane of the potential sensor shall be perpendicular to the axis of the pipeline, and the lateral surface of the pipeline should be free from defects in insulation. Reference electrodes PSS-ENES-RE-4M are supplied in bags with stabilizing filler.
Advantages
- Sealed two-piece casing, shockproof
- Due to design features, the electrode remains operational regardless of its position in the ground, but the best position is with the membrane upwards, which increases the service life of the product
- PSS-ENES-RE-4M is immersed in a bag with hygroscopic filler, thanks to which it works perfectly even in dry periods.
We complete it with a cable at the request of the customer.
| Parameter | Value |
|---|---|
| 1. Internal electrical resistance, maximum, kOhm | 1.0 |
| 2. Potential relative to silver chloride electrode, mV | 100±20 |
| 3. Body internal diameter, mm | 82 |
| 4. Amount of electrolyte poured into the body, ml | 800 |
| 5. Conductor length, minimum, m* | 5 |
| 6. Cable type | 2 copper wires, 4 mm² cross-section area, PVC insulated, shielded |
| 7. Electrode full weight (with 5 m cable), maximum, kg | 4.0 |
| 8. Service lifetime, years** | 25 |
*Cable length and grade can be changed upon Customer's request. The length of the cable leads can be from 1.7 m to 300 m.
**The service life of the electrode may be reduced depending on the service life of the cable